 Current Transducer HTA 100..1000-S
For the electronic measurement of DC, AC and pulsed currents, with a galvanic isolation between the primary (high power) circuit and the secondary (electronic) circuit.
IPN = 100..1000 A
Electrical data
Primary nominal current rms IPN (A) 100 200 300 400 500 600 1000 Primary current measuring range IPM (A) 300 600 900 1000 1000 1000 1000 Type RoHS since date code 46179 46170 46097 46100 46083 46222 46118
Features
* Open loop transducer using
Hall Effect
HTA HTA HTA HTA HTA HTA HTA
100-S 200-S 300-S 400-S 500-S 600-S 1000-S
* Panel mounting - Horizontal or
Vertical
* Insulated plastic case recognized
according to UL 94-V0
IP VOUT RL VC IC Vb Vd Ris
Overload capability Output voltage (Analog) @ IPN Load resistance TA = 0 .. + 70C TA = - 25 .. + 85C Supply voltage ( 5 %) Current consumption Rated isolation voltage rms1) Rms voltage for AC isolation test, 50 Hz, 1 min Isolation resistance @ 500 VDC
30,000 4 >1 >3 15 < 25 500 3 > 500
A V k k V mA V kV M
Advantages
* * * * * *
Very good linearity Very good accuracy Low temperature drift Wide frequency bandwidth Very low insertion losses High immunity to external interference * Current overload capability * Low power consumption * Wide dynamic range, 100 to 1000 A in one package.
Accuracy - Dynamic performance data
X
L
VOE VOH TCVOE TCVOUT tr di/dt BW
Accuracy 2) @ IPN, TA = 25C, @ 15 V Linearity error 2) (0 .. IPN) Electrical offset voltage @ IP = 0, TA = 25C Hysteresis offset voltage @ IP = 0, after an excursion of 3 x IPN Temperature coefficient of VOE TA = - 25 .. + 85C Temperature coefficient of VOUT TA = - 25 .. + 85C Response time to 90 % of IPN step di/dt accurately followed Frequency bandwidth (- 3 dB) 3)
1 0.5 < 10
% % mV
< 10 mV <1 mV/K < 0.05 %/K <3 s > 50 A/s DC .. 50 kHz
Applications
* AC variable speed drives and servo
motor drives
General data
TA TS m Ambient operating temperature Ambient storage temperature Mass Standards Safety EMC Deviation in output when tested to EN 61000-4-3 Notes :
1) 2)
* Static converters for DC motor drives * Battery supplied applications * Uninterruptable Power Supplies
(UPS)
- 25 .. + 85 - 25 .. + 85 230
C C g
* Switched Mode Power Supplies
(SMPS)
* Power supplies for welding
applications.
EN50178 (1994) EN50082-2(1992) EN50081-1(1992)
< 25
% of IPN
Application domain
* Industrial
Overvoltage Category III, Pollution Degree 2 Excludes the electrical offset 3) Refer to derating curves in the technical file to avoid excessive core heating at high frequency
Page 1/2
070110/4
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com
Dimensions HTA 100..1000-S (in mm. 1 mm = 0.0394 inch) Bottom view Left view
Secondary terminals
Terminal Terminal Terminal Terminal 1 2 3 4 : supply voltage + 15 V : supply voltage - 15 V : output : 0V
Front view Mechanical characteristics
* General tolerance * Primary through-hole * Connection of secondary
0.5 mm O 32 mm Molex 5045-04A
Safety
This transducer must be used in electric/electronic equipment with respect to applicable standards and safety requirements in accordance with the following manufacturer's operating instructions.
Remarks
* VOUT is positive when IP flows in the direction of the arrow. * Temperature of the primary conductor should not exceed
90C. * This is a standard model. For different versions (supply voltages, secondary connections, unidirectional measurements, operating temperatures, etc.) please contact us. Caution, risk of electrical shock When operating the transducer, certain parts of the module can carry hazardous voltage (eg. primary busbar, power supply). Ignoring this warning can lead to injury and/or cause serious damage. This transducer is a built-in device, whose conducting parts must be inaccessible after installation. A protective housing or additional shield could be used. Main supply must be able to be disconnected.
Page 2/2
070110/4
LEM reserves the right to carry out modifications on its transducers, in order to improve them, without prior notice.
www.lem.com


▲Up To Search▲   

 
Price & Availability of HTA100-S07

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X